Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
System Diagnosis
Shortage of refrigeran
Potential Causes & Solutions
Refrigerant shortage and refrigerant clogging (wrong piping).
Defective thermistor.
Defective low pressure sensor.
Defective outdoor unit main PCB.
Verify Before Replacing Parts
Confirm the exact Daikin model family and packaged context before acting on a generic code description.
Verify airflow first, then confirm operating pressures and temperature relationship before adjusting charge.
Look for restrictions, iced coils, or dirty heat-transfer surfaces that can mimic a charge problem.
After the correction, run the system long enough to confirm the code does not return under normal load.
Field Signals to Confirm
What usually confirms it
Pressure and temperature readings that stay out of range after airflow is verified.
What can fool you
Dirty coils or airflow restrictions can look like a charge problem until the air side is cleaned up.
When to Escalate the Call
You suspect a restriction, leak, or compressor issue that needs deeper system evaluation.
The readings do not normalize after airflow and coil conditions are corrected.
Diagnose with Confidence
Use the ACLogics AI assistant to walk through this error code step-by-step.