Published codes
Variable Capacity or Emergency Mode
Variable Capacity or Emergency Mode. Outdoor unit is operating in variable-capacity or emergency mode.
Communications Loss
Communications Loss. Communication with the control/UI has been lost.
Invalid Model
Invalid Model. Invalid model or model-plug information detected.
High Pressure Switch Open
High Pressure Switch Open. High-pressure switch is open; board indicates the event and retries after 15 minutes.
Low Pressure Trip
Low Pressure Trip. Low-pressure trip detected; board indicates the event and retries after 15 minutes.
Compressor Winding Fault
Compressor Winding Fault. Compressor winding fault detected.
Brownout Event
Brownout Event. Brownout event detected; control reverts to 5-minute cycle delay.
Lost Inverter Communications
Lost Inverter Communications. Inverter communication was lost.
230VAC Dropout-Reset Event
230VAC Dropout-Reset Event. 230VAC dropout/reset event detected; control reverts to 5-minute cycle delay.
Outdoor Air Temp Sensor Fault
Outdoor Air Temp Sensor Fault. Outdoor air temperature sensor fault detected.
Suction Temp Sensor Fault
Suction Temp Sensor Fault. Suction temperature sensor fault detected.
Coil Temp Sensor Fault
Coil Temp Sensor Fault. Coil temperature sensor fault detected.
OAT-OCT Thermistor Out of Range
OAT-OCT Thermistor Out of Range. Outdoor-air / outdoor-coil thermistor reading is out of range.
Suction Pressure Sensor Fault
Suction Pressure Sensor Fault. Suction pressure sensor fault detected.
Lost Inverter Communication Event
Lost Inverter Communication Event. Lost inverter communication event detected.
Compressor Scroll Temp Out of Range Event
Compressor Scroll Temp Out of Range Event. Compressor scroll temperature is out of range.
Compressor No Start
Compressor No Start. Compressor failed to start.
Compressor Sump Heater Active
Compressor Sump Heater Active. Compressor sump heater is active.
Inverter Internal Fault
Inverter Internal Fault. Internal inverter fault detected.
Compressor Motor Temp Out of Range Event
Compressor Motor Temp Out of Range Event. Compressor motor temperature is out of range.
Suction Over Temp Event
Suction Over Temp Event. Suction over-temperature event detected.
Inverter Temp Out of Range Event
Inverter Temp Out of Range Event. Inverter temperature is out of range.
Inverter Over Current Event
Inverter Over Current Event. Inverter over-current event detected.
Compressor No-Pump Event
Compressor No-Pump Event. No-pump condition detected at compressor.
Suction Over Temp Lockout
Suction Over Temp Lockout. Suction over-temperature lockout active for 4 hours.
Low Pressure Lockout For 4 Hours
Low Pressure Lockout For 4 Hours. Low-pressure lockout active for 4 hours.
High Pressure Lockout For 4 Hours
High Pressure Lockout For 4 Hours. High-pressure lockout active for 4 hours.
Compressor Temp Lockout
Compressor Temp Lockout. Compressor temperature lockout active for 4 hours.
Inverter Cable Fault
Inverter Cable Fault. Inverter cable fault detected.
Inverter VDC-Out Over Voltage Event
Inverter VDC-Out Over Voltage Event. Inverter VDC output over-voltage event detected.
Inverter VDC-Out Under Voltage Event
Inverter VDC-Out Under Voltage Event. Inverter VDC output under-voltage event detected.
230VAC Under Voltage Event
230VAC Under Voltage Event. 230VAC under-voltage event detected.
230VAC Over Voltage Event
230VAC Over Voltage Event. 230VAC over-voltage event detected.
High Current Lockout
High Current Lockout. High-current lockout active for 2 hours.
VDC Under Voltage Lockout
VDC Under Voltage Lockout. VDC under-voltage lockout active for 2 hours.
VDC Over Voltage Lockout
VDC Over Voltage Lockout. VDC over-voltage lockout active for 2 hours.
High Torque Event
High Torque Event. High-torque event detected.
High Torque Lockout
High Torque Lockout. High-torque lockout active for 2 hours.
Standby
Standby. Unit is powered and in standby with amber LED on and no flash.
Variable Speed Range Cutback
Variable Speed Range Cutback. Amber LED pattern is 2 seconds on with a longer pause and 1 second off, indicating variable-speed range cutback.