Error Code 43

Troubleshooting guide for the Carrier Furnaces system fault 43.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.

System Diagnosis

Low-Heat Pressure Switch Open While High-Heat Pressure Switch Is Closed. Check low inlet gas pressure, plugged drain, improper pressure-switch wiring, water in vent piping, or obstructed tubing.

Potential Causes & Solutions

  • Check low inlet gas pressure at manifold.
  • Verify condensate drain is clear.
  • Inspect pressure switch wiring connections.
  • Check for water accumulation in vent piping.
  • Clear any obstructed tubing.

Verify Before Replacing Parts

  1. Confirm the exact Carrier model family and furnaces context before acting on a generic code description.
  2. Verify airflow first, then confirm operating pressures and temperature relationship before adjusting charge.
  3. Look for restrictions, iced coils, or dirty heat-transfer surfaces that can mimic a charge problem.
  4. After the correction, run the system long enough to confirm the code does not return under normal load.

Field Signals to Confirm

What usually confirms it

Pressure and temperature readings that stay out of range after airflow is verified.

What can fool you

Dirty coils or airflow restrictions can look like a charge problem until the air side is cleaned up.

When to Escalate the Call

  • You suspect a restriction, leak, or compressor issue that needs deeper system evaluation.
  • The readings do not normalize after airflow and coil conditions are corrected.

Diagnose with Confidence

Use the ACLogics AI assistant to walk through this error code step-by-step.

Included in Diagnosis Workflow

1

Ask

Upload nameplate & symptoms

2

Diagnose

AI isolates the likely furnaces branch behind code 43

3

Report

Document the verified result and next action

Related Carrier Furnaces Codes