What It Means
- OD Inverter High Main Input Current

Equipment not specified:
Priority condition: Service Soon/Service Urgent The inverter has detected a high main input current condition. • If condition is detected, outdoor unit will stop (compressor and fan) – moderate condition. • Anti-short cycle is initiated. • If condition occurs 10 times within an hour, system will lockout – critical condition. • Inverter LEDs will flash code 22. • Refer to the unit service documentation for detailed troubleshooting procedures. Priority condition: Service Soon/Service Urgent Inverter flash code 22. Priority condition: Service Soon/Service Urgent The sequence is: • Red LED: Two Flashes • Green LED: Two Flashes NOTE: Inverter normal operations with no error code present is as follows. Red LED is ON and Green LED is OFF.
OD Inverter High Main Input Current
Continue in ACLogics with guided diagnosis for your equipment and symptoms.