System Diagnostics

Know It's the Board Before You Order One

Ductless faults are easy to misread. ACLogics walks you through communication errors, inverter boards and expansion valve problems so you don't replace parts that weren't broken.

FAULT SYMPTOM

Communication error (E6/U4)

CHECK 01

Measure DC voltage between terminal S1 and S3. Is it pulsing?

Pulsing between 0V and 24VDC
DIAGNOSIS

Electrical noise from unshielded wires. Verify proper S3 shield grounding at outdoor unit.

Stuck solid at 0V or 24VDC
CHECK 02

No pulsing detected. Measure voltage level.

0VDC — No power from outdoor board24VDC Solid — Indoor sending, no reply

Complete diagnostic tree — every branch, every fault path

Try ACLogics Free — iPhone & Android

What You'll Stop Guessing About

Know what failed before you order the part.

Find the Break in a Communication Error

Check the signal between the indoor and outdoor units step by step, so you know whether it's a board or the wire.

Spot a Bad Sensor Fast

Compare thermistor resistance against temperature, so a drifted sensor doesn't get blamed on the board.

Test Before You Condemn the Inverter Board

Follow safe checks on the high-voltage side before you order an expensive board.

How a Call Goes

01

Enter the Code

Enter the error code or blink pattern for context on the unit you're working on.

02

Narrow It Down

Follow guided checks to tell the indoor board, outdoor board and compressor side apart.

03

Confirm It's Running

Check communication is back and the compressor ramps up properly.

Deployment

Simple, Transparent Pricing

Pick a plan when your whole team needs it on every call.

Free Plan

$0

Explore the core workflow at no cost.

Pro Plan

$14.99 /month

Built for independent experts.

Team Plan

$99 /month · up to 5 members

Standard for growing HVAC shops.

Frequently Asked Questions

I have a communication error (E1/E7). Is it always the outdoor board?

No. It can be the indoor board, the wire harness, or even a reactor. We guide you through checking the S-terminal voltage loop to pinpoint the break.

The compressor starts but shuts down after a few seconds. Why?

This often points to IPM failure, low DC bus voltage, or compressor lockup. Our workflow helps you test the IPM diode drops and compressor windings.

Do I need special tools for mini-split diagnostics?

A good multimeter with True RMS and a clamp are essential. An oscilloscope is helpful but not required if you follow our voltage-based communication checks.

Know What to Check Next on Your Next Call

Get the checks in order, confirm the cause, and fix it right the first time.