Find the Break in a Communication Error
Check the signal between the indoor and outdoor units step by step, so you know whether it's a board or the wire.
Ductless faults are easy to misread. ACLogics walks you through communication errors, inverter boards and expansion valve problems so you don't replace parts that weren't broken.
Communication error (E6/U4)
Measure DC voltage between terminal S1 and S3. Is it pulsing?
Electrical noise from unshielded wires. Verify proper S3 shield grounding at outdoor unit.
No pulsing detected. Measure voltage level.
Complete diagnostic tree — every branch, every fault path
Try ACLogics Free — iPhone & AndroidKnow what failed before you order the part.
Check the signal between the indoor and outdoor units step by step, so you know whether it's a board or the wire.
Compare thermistor resistance against temperature, so a drifted sensor doesn't get blamed on the board.
Follow safe checks on the high-voltage side before you order an expensive board.
Enter the error code or blink pattern for context on the unit you're working on.
Follow guided checks to tell the indoor board, outdoor board and compressor side apart.
Check communication is back and the compressor ramps up properly.
No. It can be the indoor board, the wire harness, or even a reactor. We guide you through checking the S-terminal voltage loop to pinpoint the break.
This often points to IPM failure, low DC bus voltage, or compressor lockup. Our workflow helps you test the IPM diode drops and compressor windings.
A good multimeter with True RMS and a clamp are essential. An oscilloscope is helpful but not required if you follow our voltage-based communication checks.
Get the checks in order, confirm the cause, and fix it right the first time.