Lennox Equipment not specified

Lennox Error Code 431

Equipment not specified:

What It Means

  • OD Inverter PFC Fault

Causes & actions from Lennox

How it shows
  • iComfort S30 alert: 431
  • s30 inverter flash code: 27

Priority condition: Service Soon/Service Urgent The inverter has detected a PFC circuit over-current condition. • Error occurs when PFC detects an over current condition of 100A peak. • If condition is detected, outdoor unit will stop (compressor and fan) – moderate condition. • Anti-short cycle timer is initiated. • If condition occurs 10 times within 60 consecutive minutes, the system will lockout – critical condition. • Inverter LEDs will flash code 27. • Refer to the unit service documentation for detailed troubleshooting procedures. Priority condition: Service Soon/Service Urgent Inverter flash code 27. Priority condition: Service Soon/Service Urgent The sequence is: • Red LED: Two Flashes • Green LED: Seven Flashes NOTE: Inverter normal operations with no error code present is as follows. Red LED is ON and Green LED is OFF.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →