Lennox Zone controller

Lennox Error Code 0010

Zone controller

What It Means

  • Defrost while gas heat selected

Causes & actions from Lennox

How it shows
  • harmony diagnostic led1234: 0010 (led1: off, led2: off, led3: on, led4: off)

System detected defrost signal at W1-Def terminal block while the jumper is selected for the furnace. May be caused by: • Wrong selection for indoor unit jumper. • Outdoor unit terminal block misfired. • Zone control system failure. Check unit installation instructions for correct wiring. If no signal is present at W1, then replace zone control panel.