Lennox Unit controller

Lennox Error Code 187

Unit controller

What It Means

  • INVERTER MINOR

Causes & actions from Lennox

How it shows
  • M4 alarm code: 187

• Alarming Value = Inverter error code • Possible alarming values for Alarm 187 are: > 12 - High Comp Current > 13 - High Heat sink temperature > 14 - High PFC input current • If the alarm continues after outdoor conditions have moderated, check the fan, charge and coil. Alarm 187 will automatically clear when minimum off time expires. • Refer to trouble shooting guide in service manual for more information.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.