What It Means
- CBK48MVT, CBX40UHV: To clear error codes stored in memory, continue to HOLD push button while the three horizontal bars are displayed. Release push button when solid c is displayed.
- CBK48MVT: Clear-history branch: continue holding while solid bars displayed, release when solid c appears. Solid c starts blinking. Display blinks up to10seconds; press and release during window to confirm deletion. If10seconds expire OR pushbutton is not released, exit error mode without deleting history.
- CBK48MVT: Push and hold for one (1) second, release button. Seven-segment will display 0000 and exit error recall mode.
- CBX40UHV: Push button to confirm command to delete codes. Error codes are cleared.