What It Means
- CBK48MVT: Communications with the refrigerant detection sensor has been lost or interrupted.
- 3WPD036S6S-1P: Indoor fan error

Split & Multi-Split
E154 means different things on different Split & Multi-Split models. Enter your model number to see only your reading, or find your model below.
Models: CBK48MVT
There may be an issue with the wiring harness connecting the sensor of the refrigerant detection system to the indoor unit control board, either with the wiring itself or with the connector (see figure 2). Check the wiring and the connector for damage or improper connectivity. Check the sensor for damage or signs that it must be replaced. This fault clears when communications with the sensor has been reestablished, but latches for a minimum of 5 minutes. Retest of the presence of fault can be effected by pressing the RDS test button on the indoor unit control board.
Communications with the refrigerant detection sensor has been lost or interrupted.
Models: 3WPD036S6S-1P
Mini-split unit (outdoor)
Check on indoor unit indoor Fan operation
Indoor fan error
Continue in ACLogics with guided diagnosis for your equipment and symptoms.