Lennox Split & Multi-Split

Lennox Error Code E484

Split & Multi-Split

E484 means different things on different Split & Multi-Split models. Enter your model number to see only your reading, or find your model below.

What It Means

  • System EEV coil current too low. Heat pump operation can continue. Check system EEV coil connection to the EEV controller.
  • 3WPD036S6S-1P: PFC Overload (Over current) Error

Causes & actions from Lennox

System EEV coil current too low. Heat pump operation can continue. Check system EEV coil connection to the EEV controller.

10 models

EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060, SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060

Heat pump (outdoor)

How it shows
  • Outdoor control 7-segment display: E484

System EEV coil current too low. Heat pump operation can continue.

Other manual wording

SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060

System EEV coil current too low. Heat pump operation can continue. Check system EEV coil connection to the EEV controller

Applicable models & manual sources
  • EL21KLV

    System EEV coil current too low. Heat pump operation can continue. Check system EEV coil connection to the EEV controller.

    EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060

    EL21KLV manual, page 50

  • EL21KLV

    System EEV coil current too low. Heat pump operation can continue. Check system EEV coil connection to the EEV controller

    EL21KLV manual, page 41

  • SL22KLV

    System EEV coil current too low. Heat pump operation can continue. Check system EEV coil connection to the EEV controller

    SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060

    SL22KLV manual, page 36

PFC Overload (Over current) Error

Models: 3WPD036S6S-1P

Mini-split unit (outdoor)

How it shows
  • mini outdoor inverter pcb: E484
  • Mini-split outdoor main board: E484

Check Outdoor Inverter PBA.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.