What It Means
- Suction pressure transducer fault.

Split & Multi-Split: Air conditioner (outdoor), Heat pump (outdoor)
Suction pressure transducer is out of range. The signal should be between 0.5 VDC and 4.5 VDC between blue and black. The error code will be cleared when proper signal is provided.
EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060, EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060, EL21KLV,…
Suction pressure transducer is out of range. The signal should be between 0.5 VDC and 4.5 VDC between blue and black. The error code will be cleared when proper signal is provided. System controlled by a conventional 24VAC heat pump thermostat will operate in the staged mode.
Suction pressure transducer fault.
EL18XCV, EL18XCV-024, EL18XCV-036, EL18XCV-048, EL18XCV-060
Suction pressure transducer fault.
EL22KCV, EL22KCV-024, EL22KCV-036, EL22KCV-048, EL22KCV-060
Suction pressure transducer fault.
SL25KCV, SL25KCV-024, SL25KCV-036, SL25KCV-048, SL25KCV-060
Suction pressure transducer fault.
SL28XCV, SL28XCV-024, SL28XCV-036, SL28XCV-048, SL28XCV-060
Suction pressure transducer fault.
EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060
Suction pressure transducer fault.
EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060
Suction pressure transducer fault.
EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060
Suction pressure transducer fault.
SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060
Continue in ACLogics with guided diagnosis for your equipment and symptoms.