EL18XCV, EL18XCV-024, EL18XCV-036, EL18XCV-048, EL18XCV-060, EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060, EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060, EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060, EL22KCV, EL22KCV-024, EL22KCV-036, EL22KCV-048, EL22KCV-060, SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060, SL25KCV, SL25KCV-024, SL25KCV-036, SL25KCV-048, SL25KCV-060, SL28XCV, SL28XCV-024, SL28XCV-036, SL28XCV-048, SL28XCV-060
Air conditioner (outdoor), Heat pump (outdoor)
How it shows - Outdoor control 7-segment display: E410
Unit pressure is below the lower limit. The system is shut down. The suction pressure transducer emulates a low pressure switch, the unit does not have a low pressure switch. The cut-out is set at 40 PSIG and the cut-in set at 90 PSIG. Confirm that the system is properly charged with refrigerant. Check TXV, indoor unit blower motor, dirty filters or clogged refrigerant filter. Confirm that the evaporator coil is clean. The alarm clears after the pressure rises above 90 PSIG.
Other manual wording (1 of 4)
SL25KCV, SL25KCV-024, SL25KCV-036, SL25KCV-048, SL25KCV-060, SL28XCV, SL28XCV-024, SL28XCV-036, SL28XCV-048, SL28XCV-060
Unit pressure is below the lower limit. The system is shut down. The cut-out is set at 25 PSIG and the cut-in set at 40 PSIG. Confirm that the system is properly charged with refrigerant. Check TXV, indoor unit blower motor, dirty filters or clogged refrigerant filter. Confirm that the evaporator coil is clean. The alarm clears after the pressure rises above 40 PSIG.
Other manual wording (2 of 4)
SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060
Unit pressure is below the lower limit. The system is shut down. The cut-out is set at 35 PSIG and the cut-in set at 80 PSIG. SL22KLV does not have a Low Pressure switch, the low pressure switch is emulated by the suction pressure transducer. Confirm that the system is properly charged with refrigerant. Check TXV, indoor unit blower motor, dirty filters or clogged refrigerant filter. Confirm that the evaporator coil is clean. Confirm the suction pressure transducer is providing the correct suction pressure reading compared to manifold gauge pressure, if not check pressure tranducer connections. The alarm clears after the pressure rises above 80 PSIG.
Other manual wording (3 of 4)
EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060
Unit pressure is below the lower limit. The system is shut down. The suction pressure transducer emulates a low pressure switch, the unit does not have a low pressure switch. The cut-out is set at 35 PSIG and the cut-in set at 80 PSIG. Confirm that the system is properly charged with refrigerant. Check TXV, indoor unit blower motor, dirty filters or clogged refrigerant filter. Confirm that the evaporator coil is clean. The alarm clears after the pressure rises above 80 PSIG.
Other manual wording (4 of 4)
EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060
Unit pressure is below the lower limit. The system is shut down. The suction pressure transducer emulates a low pressure switch, the unit does not have a low pressure switch. The cut-out is set at 35 PSIG and the cut-in set at 80 PSIG. Confirm that the system is properly charged with refrigerant. Check TXV, indoor unit blower motor, dirty filters or clogged refrigerant filter. Confirm that the evaporator coil is clean. The alarm clears after the pressure rises above 90 PSIG.
Applicable models & manual sources
- EL18XCV
The outdoor unit cycled off due to low suction pressure.
EL18XCV, EL18XCV-024, EL18XCV-036, EL18XCV-048, EL18XCV-060
EL18XCV manual, page 37
- EL18XPV
The outdoor unit cycled off due to low suction pressure.
EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060
EL18XPV manual, page 37
- EL22KCV
The outdoor unit cycled off due to low suction pressure.
EL22KCV, EL22KCV-024, EL22KCV-036, EL22KCV-048, EL22KCV-060
EL22KCV manual, page 40
- SL25KCV
The outdoor unit cycled off due to low suction pressure.
SL25KCV, SL25KCV-024, SL25KCV-036, SL25KCV-048, SL25KCV-060
SL25KCV manual, page 36
- SL28XCV
The outdoor unit cycled off due to low suction pressure.
SL28XCV, SL28XCV-024, SL28XCV-036, SL28XCV-048, SL28XCV-060
SL28XCV manual, page 30
- SL22KLV
The outdoor unit cycled off due to low suction pressure.
SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060
SL22KLV manual, page 43
- EL21KLV
The outdoor unit cycled off due to low suction pressure.
EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060
EL21KLV manual, page 46
- EL19KPV
The outdoor unit cycled off due to low suction pressure.
EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060
EL19KPV manual, page 43