- Home
- Error Codes
- Lennox
- Models
- MPA
Lennox MPA Error Codes
Mini-split unit · Split & Multi-Split
Model numbers in this family: MLA, MPA, MPB
- -- Multi zone mode conflict - - (dash dash) indoor display or operation lamp Flashes 6…
- CF CF anti-cold blow. Fan will stay Off on call for heat unit indoor coil warms up to 90°F…
- CL When the LED displays CL, this is a reminder to check and clean the air filter.
- CP When the LED displays CP, this indicates the J1 jumper removed or loose or the remote on…
- E0 Outdoor unit EEPROM parameter error
- E2 Communication malfunction between indoor and outdoor units
- E3 Communication malfunction between IPM board and outdoor main control board
- E4 Outdoor temperature sensor (coil sensor T3,ambient sensor T4, Compressor discharge sensor…
- E5 Over-voltage or under-voltage protection
- E6 PFC module protection
- E8 Outdoor fan speed malfunction
- F1 No. A Indoor unit coil outlet temperature sensor malfunction
- F2 No. B Indoor unit coil outlet temperature sensor malfunction
- F3 No. C Indoor unit coil outlet temperature sensor malfunction
- F4 No. D Indoor unit coil outlet temperature sensor malfunction
- F5 No. E Indoor unit coil outlet temperature sensor malfunction
- F6 No. F Indoor unit coil outlet temperature sensor malfunction
- FC In forced cooling mode, the LED displays “FC” or alternative displays between running…
- FP Freeze protection. The silence (FP) button was pushed and held for more than three…
- Flash Flash Outdoor unit error.
- Flash Flash / Flash Flash / Flash Flash Control chip communication error.
- Flash Flash / Flash Flash / ON Driver EEPROM error.
- Flash Flash / Flash Flash / Off Driver chip start-up failure.
- Flash Flash / ON / Flash Flash Could be one of the following: • Driver phase loss protection • Driver zero speed…
- Flash Flash / ON / ON DC bus voltage is too high or to low protection.
- Flash Flash / Off / Flash Flash IGBT over-current or IPM over-current
- Flash Flash / Off / ON Could be one of the following: • Indoor and outdoor unit communication error. • Outdoor…
- LC In low ambient cooling mode, the LED displays “LC” or alternative displays between…
- LP Low ambient temperature protection
- NF When the LED displays NF, this indicates 2880 hour filter replacement reminder. To clear…
- ON / ON / Off Normal operation
- On Normal operation
- P1 High pressure protection
- P2 Low pressure protection
- P3 Current overload protection
- P4 Temperature protection of compressor discharge
- P5 Condenser high temperature protection
- P6 Inverter module (IPM) malfunction
- PH In compressor pre-heating, The LED displays “PH” or alternative displays between running…
- RO During the oil return process, The LED displays “RO” or alternative displays between…
- Slow Flash Standby
- Slow Flash / Off / ON Stand-by
- dF In defrosting mode, the LED displays “dF” or alternative displays between running…
Reference only. Confirm against the manual for your exact model. Data release 105f66ecb9e96e5dc473025d.