Lennox V36C***S4-4P Error Codes
VRF indoor unit · VRF / VRV
- E101 No communication occurs between the indoor and outdoor units for 2 minutes.
- E102 Communication error received from the outdoor unit
- E108 Error of duplicated communication addresses (NASA only)
- E109 The communication address is not confirmed. (NASA only)
- E121 Open or short circuit error of the indoor-temperature sensor
- E122 Open or short circuit error of the evaporator-in sensor
- E123 Open or short circuit error of the evaporator-out sensor
- E128 3. The evaporator-in sensor is detached.
- E129 4. The evaporator-out sensor is detached.
- E151 Error due to the opened EEV (2nd detection)
- E152 2. Error due to the closed EEV (2nd detection)
- E153 Error of the second detection of the float switch
- E154 Error of the fan in the indoor unit
- E161 Error of mixed operation
- E162 EEPROM error
- E163 EEPROM option error
- E164 Error of incompatibility of the indoor unit
- E180 18. Simultaneous opening of the cooling and heating MSB SOL valves (1st detection)
- E181 19. Simultaneous opening of the cooling and heating MSB SOL valves (2nd detection)
- E198 Open circuit error of the thermal fuse
- E201 The number of the installed indoor units that is transmitted via communication after the…
- E202 Error of 3 minute tracking on the outdoor unit
- E221 1. Open or short circuit error of the outdoor-temperature sensor
- E237 2. Open or short circuit error of the condenser sensor
- E241 5. The condenser mid sensor is detached.
- E251 3. Open or short circuit error of the discharge sensor
- E301 13. The high pressure sensor is detached.
- E306 14. The low pressure sensor is detached.
- E403 12. The compressor stops due to freeze detection (6th detection)
- E410 17. Compressor shutdown due to the low-pressure-sensor prevention control_1
- E413 16. Outdoor sump down_1 prevention control
- E416 9. Abnormal high temperature on the air discharged from the outdoor unit (2nd detection)
- E425 11. Error of detection of a reverse phase
- E428 15. Compression ratio error of the outdoor unit
- E451 8. Low pressure switch (2nd detection)
- E554 6. Refrigerant leakage (2nd detection)
- E559 10. The indoor unit stops due to an unknown error of the outdoor unit.
- ice_blue: flashing every10seconds, yellow_green: off, blue: off, red: off In the defrost operation (blinking once every 10 seconds)
- ice_blue: flashing every2seconds, yellow_green: off, blue: off, red: off Power reset (blinking once every 2 seconds)
- ice_blue: flashing, yellow_green: flashing, blue: flashing, red: off MDS (Motion Detecting Sensor) Error
- ice_blue: off, yellow_green: flashing, blue: off, red: off Communication errors other then the errors listed above
- ice_blue: off, yellow_green: off, blue: flashing, red: off Self-diagnosis errors other than the errors listed above