Lennox Equipment not specified

Lennox Error Code 446

Equipment not specified:

What It Means

  • OD Low Suction Pressure Fault

Causes & actions from Lennox

How it shows
  • iComfort S30 alert: 446

Priority condition: Service Soon/Service Urgent Suction pressure < 40 psig in operation. Error code initially will be a moderate and will escalate to critical and stop system operation. After 5-strikes during a single thermostat demand. Recommend replacement of low pressure switch.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →