Lennox Ducted Heating

Lennox Error Code E228

Ducted Heating

E228 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.

What It Means

  • Combustion air inducer calibration failure
  • SLP98UHV, SLP99UHV: Unable to perform successful pressure switch calibration.

Causes & actions from Lennox

Combustion air inducer calibration failure

6 models

EL280UHEK, EL280UHEK(X), EL297UHEK, SL280DFNV, SL280UHV, SL297UHNV

Gas furnace (indoor)

How it shows
  • Integrated control 7-segment display: E228

Unable to perform pressure switch calibration. Check vent system and pressure switch wiring connections. Resumes normal operation after fault is cleared.

Applicable models & manual sources

Unable to perform successful pressure switch calibration.

Models: SLP98UHV, SLP99UHV

How it shows
  • Integrated control 7-segment display: E228

Retry after 300 seconds. Error counter cleared when exit- ing lockout, unable to perform pressure switch calibration. Check vent system and pressure switch wiring connec- tions.

Other manual wording

SLP99UHV

Retry after 300 seconds. Error counter cleared when exiting lockout, unable to perform pressure switch calibration. Check vent system and pressure switch wiring connections.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →