- Thermostat Lost Connection Or Internal Fault

Equipment not specified:
Priority condition: Service Urgent • HD wall display not detected for more than 30 seconds. • Solid blue LED will appear on mag-mount if powered. Only on versions with mag-mount. • Flashing blue LED will appear if not communicating with smart hub. Only on versions with mag- mount. • Typically the thermostat will send a command to the unknown device and place it in a soft disable state. The Lennox communicating control with the soft disable state will indicate so as follows: • On air handler, furnace and outdoor controls, the state is displayed by double horizontal lines on seven-segment display. • On the damper control module, the green LED will flash 3 seconds on and 1 second off. • On the equipment interface module, the green LED will flash 3 seconds on and 1 second off. Cycling power to the soft disabled control may clear the condition. If cycling power does not clear the soft disable state then replace control.
Thermostat Lost Connection Or Internal Fault