What It Means
- Discharge Line Temperature Discharge Sensor Lockout

Split & Multi-Split:
Discharge Line Temperature Discharge Sensor Lockout (5 strikes per code = LOCKOUT). This code detects shorted sensor or high discharge temperatures. If the discharge line temperature exceeds a temperature of 300ºF (148ºC) during compressor operation, the board will de-energize the compressor contactor output (and the defrost output if active). The compressor will remain off until the discharge temperature has dropped below 225ºF (107ºC).
XP19
Discharge Line Temperature Discharge Sensor Lockout. (Lockout occurs after 5 strikes).
Discharge Line Temperature Discharge Sensor Lockout
Discharge Line Temperature Discharge Sensor Lockout