Lennox Split & Multi-Split

Lennox Error Code DS2 OFF, DS1 Fast Flash

Split & Multi-Split:

What It Means

  • Discharge Sensor Fault

Causes & actions from Lennox

How it shows
  • defrost control ds2 ds1 led: DS2 OFF, DS1 Fast Flash (ds1: flashing (fast), ds2: off)

Discharge Sensor Fault. The board detects open sensor or out of temperature sensor range. This fault is detected by allowing the unit to run for 90 seconds before checking sensor resistance. If the sensor resistance is not within range after 90 seconds, the board will count one fault. After 5 faults, the board will lockout.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.