What It Means
- CBX40UHV: Low 24 volts (18 or less volts) - Control will restart if the error recovers.
- CBK48MVT: The 24VAC to the air-handler control is lower than the required range of 18 to 30VAC.

Split & Multi-Split
E115 means different things on different Split & Multi-Split models. Enter your model number to see only your reading, or find your model below.
Models: CBX40UHV
Air handler (indoor)
This manual entry does not list further causes or actions.
Low 24 volts (18 or less volts) − Control will restart if the error recovers.
Models: CBK48MVT
24-volt power low (range is 18 to 30 volts). Check and correct voltage. Check for addi- tional power-robbing equipment connected to system. This alarm / code may require the installation of an additional or larger VA transformer.
The 24VAC to the air-handler control is lower than the required range of 18 to 30VAC.
Continue in ACLogics with guided diagnosis for your equipment and symptoms.