Lennox Ducted Heating Error Code E115

Ducted Heating: Gas furnace (indoor)

What It Means

  • Low 24V - Control will restart if the error recovers.

Causes & actions from Lennox

How it shows
  • Integrated control 7-segment display: E115

24-Volt Power Low (Range is 18 to 30 volts). Check and correct voltage. Check for additional power-robbing equipment connected to system. May require installation of larger VA transformer to be installed in furnace / air handler. Clears after fault recovered.

Other manual wording

SLP98UHV, SLP99UHV

24 voltage low (Range is 18 to 30 volts) Check voltage.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.