Lennox Ducted Heating

Lennox Error Code E155

Ducted Heating

E155 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.

What It Means

  • Refrigerant Leak Detector Sensor #2 Communication lost
  • Refrigerant Leak Detector #2 Communication lost

Causes & actions from Lennox

Refrigerant Leak Detector Sensor #2 Communication lost

8 models

EL180UHNE(K), EL195UHNEK, EL195UHNEK-01, EL195UHNEK-02, EL196UHEK, ML180UHVK, ML193DFEK, ML196UHEK

Gas furnace (indoor)

How it shows
  • Integrated control 7-segment display: E155

There may be an issue with the wiring harness connecting the sensor #2 to the furnace control board, either with the wiring itself or with the connector. Check the wiring and the connector for damage or improper connectivity. Check the sensor for damage or obstruction on the harness plug. This fault clears when communications with the sensor has been reestablished, but blower latches for a minimum of 5 minutes. Retest of the presence of fault can be effected by pressing the Low GWP test button on the furnace unit control board

Applicable models & manual sources

Refrigerant Leak Detector #2 Communication lost

11 models

EL280UHEK, EL280UHEK(X), EL297UHEK, ML296UHVK, ML297UH045XV36BK, ML297UH070XV36BK, ML297UH090XV36CK, ML297UH090XV60CK, ML297UH110XV60CK, ML297UH135XV60DK, ML297UHVK

Gas furnace (indoor)

How it shows
  • Integrated control 7-segment display: E155

There may be an issue with the wiring harness connecting the sen- sor #1 to the furnace control board, either with the wiring itself or with the connector. Check the wiring and connector for damage or improper connectivity. Check the sensor for damage or obstruction on the harness plug. This fault clears when communicati9ons with the senor has been reestablished, but blower latches for a minimum 5 minutes. Retest of the presence of fault can be effected by press- ing the LOW GWP test button on the furnace unit control board.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.