Lennox Ducted Heating

Lennox Ducted Heating Error Code E312

Ducted Heating:

What It Means

  • Restricted air flow in cooling or continuous fan mode is lower than cfm setting.

Causes & actions from Lennox

How it shows
  • Integrated control 7-segment display: E312

Restricted airflow - Indoor blower is running at a reduced cubic feet per minute (Cutback Mode) - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating out of its designed parameters (0 to 0.8 inches water column total external static pressure). Check filter and ductwork. To clear replace filter if needed or repair/ add ductwork.

Other manual wording (1 of 2)

SLP98UHV

Restricted airflow − Indoor blower is running at a reduced cubic feet per minute (Cutback Mode) − The variable speed motor has pre−set speed and torque limiters to protect the motor from damage caused by operating out of its designed parameters (0 to 0.8 inches water column total external static pressure). Check filter and ductwork. To clear re- place filter if needed or repair/ add ductwork.

Other manual wording (2 of 2)

SL297UHNV

Warning Only. Restricted airflow - Indoor blower is running at a re- duced CFM (Cutback Mode - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating outside of design parameters (0 to 0.8” W.C.. total ex- ternal static pressure). Check filter and duct system. To clear, re- place filter if needed or repair/add duct. Cleared after the current service demand is satisfied.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.