What It Means
- Restricted air flow in cooling or continuous fan mode is lower than cfm setting.

Ducted Heating:
Restricted airflow - Indoor blower is running at a reduced cubic feet per minute (Cutback Mode) - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating out of its designed parameters (0 to 0.8 inches water column total external static pressure). Check filter and ductwork. To clear replace filter if needed or repair/ add ductwork.
SLP98UHV
Restricted airflow − Indoor blower is running at a reduced cubic feet per minute (Cutback Mode) − The variable speed motor has pre−set speed and torque limiters to protect the motor from damage caused by operating out of its designed parameters (0 to 0.8 inches water column total external static pressure). Check filter and ductwork. To clear re- place filter if needed or repair/ add ductwork.
SL297UHNV
Warning Only. Restricted airflow - Indoor blower is running at a re- duced CFM (Cutback Mode - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating outside of design parameters (0 to 0.8” W.C.. total ex- ternal static pressure). Check filter and duct system. To clear, re- place filter if needed or repair/add duct. Cleared after the current service demand is satisfied.
Restricted air flow in cooling or continuous fan mode is lower than cfm setting.
Restricted air flow in cooling or continuous fan mode is lower than cfm setting.
Restricted air flow in cooling or continu- ous fan mode is lower than cfm setting.