Lennox SLP99UHV Error Codes
Equipment type not specified · Ducted Heating
- -- Soft disable - Soft disabling is when thermostat finds a device on the BUS that it does…
- . Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF).
- A Cubic feet per minute (cfm) setting for indoor blower (1 second ON, 0.5 second OFF) / cfm…
- C Cooling stage (1 second ON, 0.5 second OFF) / 1 or 2 displayed / Pause / cfm setting…
- E105 Device communication problem - No other devices on BUS (Communication system).
- E110 Low line voltage.
- E113 High line voltage.
- E114 Line voltage frequency out-of-range.
- E115 Low 24V - Control will restart if the error recovers.
- E120 Unresponsive device.
- E124 Active communicating thermostat signal missing for more than 3 minutes.
- E125 Control failed self-check, internal error, failed hardware. Will restart if error…
- E126 Failed internal control communication between microcontrollers.
- E180 Outdoor air sensor failure - NO error if disconnected. Only shown if shorted or…
- E200 Hard lockout - Rollout circuit open or previously open.
- E201 Indoor blower communication failure - Unable to communicate with blower motor.
- E202 Indoor blower motor mis-match - Indoor motor horsepower does not match unit capacity.
- E203 Appliance capacity / size is NOT programmed. Invalid unit codes refer to configuration…
- E204 Gas valve mis-wired.
- E205 Gas valve control relay contact shorted.
- E207 Hot surface ignitor sensed open - Refer to troubleshooting in installation instruction.
- E223 Low pressure switch failed open - Refer to troubleshooting in installation instruction.
- E224 Low pressure switch failed closed - Refer to troubleshooting in installation instruction.
- E225 High pressure switch failed open - Refer to troubleshooting in installation instruction.
- E226 High pressure switch failed closed - Refer to troubleshooting in installation instruction.
- E227 Low pressure switch open during trial for ignition or run mode. Refer to troubleshooting…
- E228 Unable to perform successful pressure switch calibration.
- E240 Low flame current - Run mode - Refer to troubleshooting in installation instruction.
- E241 Flame sensed out of sequence - Flame still present.
- E250 Limit switch circuit open - Refer to troubleshooting in installation instruction.
- E252 Discharge air temperature too high (gas heat only).
- E270 Soft lockout - Exceeded maximum number of retries. No flame current sensed.
- E271 Soft lockout - Exceeded maximum number of retries. Last retry failed due to the pressure…
- E272 Soft lockout - Exceeded maximum number of recycles. Last recycle due to the pressure…
- E273 Soft lockout - Exceeded maximum number of recycles. Last recycle due to flame failure.
- E274 Soft lockout - Exceeded maximum number of recycles. Last recycle failed due to the limit…
- E275 Soft lockout - Flame sensed out of sequence from code 241 fault. Flame signal is gone.
- E276 Soft lockout - Exceeded maximum number of calibration retries.
- E290 Ignitor circuit fault - Failed ignitor or triggering circuitry.
- E291 Restricted air flow - Cubic feet per minute is lower than what is needed for minimum…
- E292 Indoor blower motor unable to start - Seized bearings, stuck wheel, etc.
- E294 Combustion air inducer motor amp draw is too high.
- E295 Indoor blower motor temperature is too high.
- E310 Discharge error sensor failure - No error if disconnected. Only shown if shorted or…
- E311 Heat rate reduced to match indoor blower air flow. Replace filter or repair duct…
- E312 Restricted air flow in cooling or continuous fan mode is lower than cfm setting.
- E313 Indoor or outdoor unit capacity mismatch.
- E331 Global network connection - Communication link problem.
- E347 No 24 Volt output on Y1 to C with non-communicating outdoor unit.
- E348 No 24 Volt output on Y2 to C with noncommunicating outdoor unit.
- E349 No 24 Volts between R & O with non-communicating outdoor unit (Dual fuel module required…
- E401 LSOM - Compressor ran more than 18 hours in air conditioning mode.
- E402 LSOM - Outdoor unit system pressure trip.
- E403 LSOM - Compressor short-cycling (Running less than 4 minutes).
- E404 LSOM - Compressor rotor locked.
- E405 LSOM - Compressor open circuit.
- E406 LSOM - Compressor open start circuit.
- E407 LSOM - Compressor open run circuit.
- E408 LSOM - Compressor contactor is welded.
- E409 LSOM - Compressor contactor is welded.
- H Heat Stage (1 second ON, 0.5 second OFF) / 1 or 2 displayed / Pause / cfm setting…
- U Discharge Air Temperature
- d Cooling stage (1 second ON, 0.5 second OFF) / 1 or 2 displayed / Pause / cfm setting…
- df Defrost mode.
- h Variable Capacity Heat (1 second ON, 0.5 second OFF) / % of input rate displayed / Pause/…