What It Means
- SLP98UHV, SLP99UHV: LSOM - Compressor rotor locked.
- SL297UHNV: LSOM - Compressor rotor locked. Compressor short-cycling. (Running less than 4 minutes).

Ducted Heating
E404 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.
Models: SLP98UHV, SLP99UHV
Compressor short cycling (Running less than 4 min- utes).
SLP99UHV
Compressor short cycling (Running less than 4 minutes).
LSOM − Compressor rotor locked.
LSOM - Compressor rotor locked.
Models: SL297UHNV
Compressor rotor locked up due to run capacitor short, bearings are seized, excessive liquid refrigerant, etc. Clears the error after 4 consecutive normal run cycles or after power reset.
LSOM - Compressor rotor locked. Com- pressor short-cycling. (Running less than 4 minutes).