Lennox SL280UHV Error Codes
Equipment type not specified · Ducted Heating
- . Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF).
- A Cubic feet per minute (cfm) setting for indoor blower (1 second ON, 0.5 second OFF) / cfm…
- C Cooling stage (1 second ON, 0.5 second OFF) / 1 or 2 displayed / Pause / cfm setting…
- E000 No error in memory
- E105 Device communication problem - No other devices on BUS (Communication system).
- E110 Low line voltage.
- E111 Low line voltage.
- E112 Ground not detected.
- E113 High line voltage.
- E114 Line voltage frequency out-of-range.
- E115 Low 24V - Control will restart if the error recovers.
- E116 High 24V.
- E117 Poor ground detected (Warning only).
- E120 Unresponsive device. Communication only.
- E124 Active communicating thermostat signal missing for more than 3 minutes.
- E125 Control failed self-check, internal error, failed hardware. Will restart if error…
- E131 Corrupted control parameters (Verify configuration of system). Communicating only.
- E150 A2L Refigerant leak alarm
- E151 A2L Sensor fault (sensor problem) (communication mode only)
- E180 Outdoor air temperature sensor failure. Only shown if shorted or out-ofrange.
- E200 Hard lockout - Rollout circuit open or previously open.
- E201 Indoor blower communication failure - Unable to communicate with blower motor.
- E202 Indoor blower motor mis-match - Indoor motor horsepower does not match unit capacity.
- E203 Appliance capacity / size is NOT programmed. Invalid unit codes refer to configuration…
- E204 Gas valve mis-wired.
- E205 Gas valve control relay contact shorted.
- E206 Gas valve second-stage relay failure
- E207 Hot surface ignitor sensed open.
- E223 Low pressure switch failed open.
- E224 Low pressure switch failed closed.
- E225 High pressure switch failed open.
- E226 High pressure switch failed closed
- E227 Pressure switch open during trial for ignition or run mode.
- E228 Combustion air inducer calibration failure
- E229 Ignition on high fire
- E240 Low flame current - Run mode.
- E241 Flame sensed out of sequence - Flame still present.
- E250 Limit switch circuit open.
- E252 Discharge air temperature too high (gas heat only).
- E270 Soft lockout - Exceeded maximum number of retries. No flame current sensed.
- E271 Soft lockout - Exceeded maximum number of retries. Last retry failed due to the pressure…
- E272 Soft lockout - Exceeded maximum number of recycles. Last recycle due to the pressure…
- E273 Soft lockout - Exceeded maximum number of recycles. Last recycle due to flame failure.
- E274 Soft lockout - Exceeded maximum number of recycles. Last recycle failed due to the limit…
- E275 Soft lockout - Flame sensed out of sequence. Flame signal is gone.
- E290 Ignitor circuit fault - Failed ignitor or triggering circuitry.
- E292 Indoor blower motor unable to start due to obstructed wheel, seized bearings.
- E295 Indoor blower motor temperature is too high.
- E310 Discharge error temperature sensor failure. Only shown if shorted or out of range.
- E311 Heat rate reduced to match indoor blower air flow.
- H Gas Heat Stage (1 second ON, 0.5 second OFF) / 1 or 2 displayed / Pause / cfm setting…
- U Discharge Air Temperature
- d Dehumidification mode (1 second ON) / 1 second OFF) / cfm setting displayed / Pause /…
- dF Defrost mode.
- h Heat pump stage (1 second ON, 0.5 second OFF) / % of input rate displayed / Pause / cfm…