Lennox Ducted Heating

Lennox Error Code E270

Ducted Heating: Gas furnace (indoor)

What It Means

  • Soft lockout - Exceeded maximum number of retries. No flame current sensed.

Causes & actions from Lennox

How it shows
  • Integrated control 7-segment display: E270

Check for proper gas flow. Ensure that ignitor is lighting burner. Check flame sensor current. Clears when heat call finishes successfully.

Other manual wording

SLP98UHV, SLP99UHV

Check for gas flow, ignitor lighting burner, flame sensor current.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →