What It Means
- SLP98UHV, SLP99UHV: Combustion air inducer motor amp draw is too high.
- SL280DFNV, SL297UHNV: Combustion air inducer over current.

Ducted Heating
E294 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.
Models: SLP98UHV, SLP99UHV
Check combustion blower bearings, wiring , am- peres, replace if it does not operate or meet perfor- mance.
SLP99UHV
Check combustion blower bearings, wiring , amperes, replace if it does not operate or meet performance.
Combustion air inducer motor amp draw is too high.
Combustion air inducer motor amp draw is too high.
Models: SL280DFNV, SL297UHNV
Check combustion blower bearings, wiring and amps. Re- place if does not operate or does not meet performance standards. Clears after inducer current is sensed to be in- range after the ignition following the soft lockout or reset.
Combustion air inducer over current.
Combustion air inducer over current.
Continue in ACLogics with guided diagnosis for your equipment and symptoms.