Lennox XC15 Error Codes
Equipment type not specified · Split & Multi-Split
- 1 Long Run Time - Compressor is running extremely long run cycles.
- 2 System Pressure Trip - Discharge or suction pressure out of limits or compressor…
- 3 Short Cycling - Compressor is running only briefly
- 4 Locked Rotor
- 5 Open Circuit
- 6 Open Start Circuit - Current only in run circuit
- 7 Open Run Circuit - Current only in start circuit
- 8 Welded Contactor - Compressor always runs
- 9 Low Voltage - Control circuit <17VAC
- GREEN ON Voltage19-28VAC present atsystemmonitorconnections.
- Green Power LED OFF Module not powering up
- Green Power LED ON Module has power
- RED ON Thermostat demand exists but no current tocompressor detected.
- Red Trip & Yellow Alert LEDs Flashing Simultaneous flashing.
- Red Trip LED ON System and compressor check out OK
- Trip & Alert LEDs flashing simultaneously Control circuit voltage too low for operation.
Reference only. Confirm against the manual for your exact model. Data release 105f66ecb9e96e5dc473025d.