Lennox Split & Multi-Split Error Code 2

Split & Multi-Split

2 means different things on different Split & Multi-Split models. Enter your model number to see only your reading, or find your model below.

What It Means

  • CBK45UHPT, CBK45UHVT: Float switch Active
  • HSXB15, XC15, XP19: System Pressure Trip Discharge or suction pressure out of limits or compressor overloaded
  • EL18KSLV: Compressor drive module hardware over current
  • XP15: System Pressure Trip - Discharge or vapor pressure out of limits or compressor overloaded

Causes & actions from Lennox

Float switch Active

Models: CBK45UHPT, CBK45UHVT

Air handler (indoor)

How it shows
  • rds noncomm red flash led: 2 (red: flashing ×2)

Check if drain line float switch is installed. If no float switch is installed, check jumper on control board.

Other manual wording

CBK45UHPT

Check if drain line float switch is installed. If no float switch is in- stalled, check jumper on control board.

Applicable models & manual sources

System Pressure Trip Discharge or suction pressure out of limits or compressor overloaded

Models: HSXB15, XC15, XP19

How it shows
  • lsom alert led: 2 (alert: flashing ×2)

1High head pressure. (cid:4) Check high pressure switch if present in system (cid:4) Check if system is overcharged with refrigerant (cid:4) Check for non−condensable in system 2Condenser coil poor air circulation (dirty, blocked, damaged). 3Condenser fan is not running. (cid:4) Check fan capacitor (cid:4) Check fan wiring and connectors (cid:4) Check fan motor for failure or blockage 4Return air duct has substantial leakage.

Other manual wording (1 of 2)

HSXB15

1 High head pressure. 2 Condenser coil poor air circulation (dirty, blocked, damaged). 3 Condenser fan is not running. 4 Return air duct has substantial leakage. 5 If low pressure switch is present, check Flash Code 1 information.

Other manual wording (2 of 2)

XC15

1High head pressure. 2Condenser coil poor air circulation (dirty, blocked, damaged). 3Condenser fan is not running. 4Return air duct has substantial leakage. 5If low pressure switch is present, see Flash Code 1 information.

Applicable models & manual sources
  • XP19

    System Pressure Trip − Discharge or suction pressure out of limits or compressor overloaded

    XP19 manual, page 22

  • XP19

    System Pressure Trip − Discharge or suction pressure out of limits or compressor overloaded

    XP19 manual, page 22

  • HSXB15

    System Pressure Trip Discharge or suction pressure out of limits or compressor overloaded

    HSXB15 manual, page 6

  • XC15

    System Pressure Trip − Discharge or suction pres- sure out of limits or compressor overloaded

    XC15 manual, page 8

Compressor drive module hardware over current

Models: EL18KSLV

Heat pump (outdoor)

How it shows
  • el18kslv outdoor fault display: 2
  • el18kslv pcb fault led: 2

IPM over current been detected by compressor drive module hardware

Applicable models & manual sources

System Pressure Trip - Discharge or vapor pressure out of limits or compressor overloaded

Models: XP15

How it shows
  • lsom alert led: 2 (alert: flashing ×2)

1Check high head pressure or discharge line sensor. 2Condenser coil poor air circulation (dirty, blocked, damaged). 3Condenser fan is not running. 4Return air duct has substantial leakage. 5If low pressure switch is present, see Flash Code 1 information.

Applicable models & manual sources
  • XP15

    System Pressure Trip − Discharge or vapor pressure out of limits or compressor overloaded

    XP15 manual, page 20

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.