Lennox Ducted Heating

Lennox Error Code 3 flashes

Ducted Heating:

What It Means

  • Before combustion blower starts: pressure OPEN? NO: check main valve OFF; hold until pressure switch OPENS. During operation pressure CLOSED? NO: main valve OFF, combustion/system fans ON; hold until switch CLOSES. The initial failed-close branch is FAST flash, not3flashes.

Causes & actions from Lennox

How it shows
  • ram diagnostic led: 3 flashes

Pressure switch failed open or failed closed (pressure switch open prior to start or failing to close / opening during operation).

Applicable models & manual sources
  • G24M

    Before combustion blower starts: pressure OPEN? NO: check main valve OFF; hold until pressure switch OPENS. During operation pressure CLOSED? NO: main valve OFF, combustion/system fans ON; hold until switch CLOSES. The initial failed-close branch is FAST flash, not3flashes.

    G24M manual, page 24

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →