Lennox G24M Error Codes
Equipment type not specified · Ducted Heating
- 2 FLASH SYSTEM LOCKOUT. FAILURE TO DETECT OR SUSTAIN FLAME.
- 2 Flashes Loss of Flame Sensed (More Than 3 Trials for Ignition)
- 3 FLASH PRESSURE SWITCH OPEN OR CLOSED.
- 3 Flashes Combustion Air Prove Switch Open
- 3 flashes Before combustion blower starts: pressure OPEN? NO: check main valve OFF; hold until…
- 4 FLASH HIGH LIMIT OR ROLLOUT SWITCH OPEN.
- 4 Flashes Primary or Secondary Limit Open
- 4 flashes Before ignition: Hi limit CLOSED? NO: check main valve OFF; hold until hi limit closes.…
- 5 FLASH FLAME SENSED AND GAS VALVE NOT ENERGIZED.
- 5 Flashes Flame Sensed Without Demand
- 5 flashes Flame OFF? NO branch: flame sensed with valve off. Lockout main valve OFF, combustion air…
- Alternating Fast Flash After15second prepurge and20second ignitor warm-up, sequential voltage above75volts /…
- FAST FLASH NORMAL OPERATION. CALL FOR HEAT.
- Fast Flash Loss of Flame Sensed Before End of 45 second Blower On Delay (3 or Fewer Trials for…
- Fast flash After combustion blower starts: pressure CLOSED? NO: check main valve OFF; hold until…
- Five Flashes Flame Sensed and Gas Valve Not Energized.
- Four Flashes Open Limit
- LED #1 & #2 Simultaneous Slow Flashes Thermostat demand satisfied: both lamps simultaneous slow flash. Combustion inducer…
- LED #1 ALTERNATING FAST FLASH / LED #2 ALTERNATING FAST FLASH Control self-check OKAY? NO branch: gas valve OFF, combustion air blower ON, indoor…
- LED #1 FAST FLASH / LED #2 FAST FLASH Thermostat calls for heat: LED1 FAST flash AND LED2 FAST flash.
- LED #1 FAST FLASH / LED #2 SLOW FLASH Polarity reversed? YES branch: LED1 FAST flash AND LED2 SLOW flash. No lamp synchrony…
- LED #1 OFF / LED #2 SLOW FLASH Initial pressure OPEN? NO branch: gas valve OFF, combustion air blower OFF, indoor blower…
- LED #1 OFF / LED #2 Slow Flash During operation pressure CLOSED? NO: gas valve de-energized, combustion inducer ON,…
- LED #1 ON / LED #2 ON Control self-check OKAY? NO branch: gas valve OFF, combustion air blower OFF, indoor…
- LED #1 ON / LED #2 SLOW FLASH Rollout CLOSED? NO: gas valve OFF, combustion air blower OFF, indoor blower OFF with…
- LED #1 ON / LED #2 Slow Flash Rollout CLOSED? NO: gas valve power OFF, combustion inducer power OFF, indoor blower OFF…
- LED #1 SLOW FLASH / LED #2 OFF Burner OFF? NO in continuous flame check: gas valve OFF, combustion air blower ON, indoor…
- LED #1 SLOW FLASH / LED #2 SLOW FLASH Burner OFF? YES: normal operation, LED1 SLOW flash AND LED2 SLOW flash.
- LED #1 Slow Flash / LED #2 Fast Flash Flame signal ABOVE0.7microamps? NO: low flame signal; does not affect control operation.…
- LED #1 Slow Flash / LED #2 ON Primary/secondary limit CLOSED? NO: gas valve de-energized, combustion inducer…
- LED #1: ALTERNATING FAST FLASH, LED #2: ALTERNATING FAST FLASH Improper main ground or line voltage below 75 volts; OR: Broken ignitor; OR: Open ignitor…
- LED #1: ALTERNATING SLOW FLASH, LED #2: ALTERNATING SLOW FLASH Watchguard - burners fail to ignite.
- LED #1: FAST FLASH, LED #2: SLOW FLASH Main power polarity reversed. Switch line and neutral.
- LED #1: OFF, LED #2: ON Circuit board failure or control wired incorrectly.
- LED #1: OFF, LED #2: SLOW FLASH Pressure switch open or has opened 5 times during a single call for heat; OR: Blocked…
- LED #1: ON, LED #2: OFF Circuit board failure or control wired incorrectly.
- LED #1: ON, LED #2: ON Circuit board failure or control wired incorrectly.
- LED #1: ON, LED #2: SLOW FLASH Rollout switch open. OR: 9 pin connector improperly attached.
- LED #1: SIMULTANEOUS FAST FLASH, LED #2: SIMULTANEOUS FAST FLASH Normal operation - signaled when heating demand initiated at thermostat.
- LED #1: SIMULTANEOUS SLOW FLASH, LED #2: SIMULTANEOUS SLOW FLASH Power - Normal operation Also signaled during cooling and continues fan.
- LED #1: SLOW FLASH, LED #2: FAST FLASH Low flame signal. Measures below .7 microAmps. Replace flame sense rod.
- LED #1: SLOW FLASH, LED #2: OFF Flame sensed without gas valve energized.
- LED #1: SLOW FLASH, LED #2: ON Primary or Secondary limit open. Units with board 63K8901 or 24L85: Limit must close…
- LED 1 Alt. Slow Flash / LED 2 Alt Slow Flash Ignition Watchguard. Four-second ignition trial: ignitor energized1second after valve…
- LED#1-Alternating Fast Flash, LED#2-Alternating Fast Flash 1.5 - On initial power-up the combustion air blower remains energgized. - DDiiagnosttiic…
- LED#1-Alternating Slow Flash, LED#2-Alternating Slow Flash 5.1 - Unit operates with a cooling and continuous fan demand. - Combustion air blower…
- LED#1-Fast Flash, LED#2-Slow Flash 1.3 - On initial power-up the comb. air blower does not energize. - Diagnostic lights…
- LED#1-Off, LED#2-Off 1.1 - Both diagnostic lights fail to light up. LED#1-Off LED#2-Off
- LED#1-Off, LED#2-Slow Flash 3.2 - Unit operates with a cooling and continuous fan demand. - Combustion air blower…
- LED#1-On, LED#2-Slow Flash 1.2 - Diagnostic lights flash the roll-out code. LED##11-OOn, LED##22-Slow Flash
- LED#1-Slow Flash, LED#2-Fast Flash 7.0 - Unit operates correctly but the diagnostic lights flash low flame sense code.…
- LED#1-Slow Flash, LED#2-On 3.1 - Unit operates with a cooling or continuous fan demand. - Combustion air blower will…
- LED#1-Slow Flash, LED#2-Slow Flash 1.4 - On initial power up the combustion air blower does not energize. - Diagnostic…
- SLOW FLASH NORMAL OPERATION. NO CALL FOR HEAT.
- STEADY ON CONTROL BOARD FAILURE.
- Slow Flash Normal Operation and No Call For Heat
- Slow flash Normal heating standby and thermostat-open end branch. At end combustion air blower stops…
- Steady On Control Failure
- Steady on Control self-check OKAY? NO branch. Control board failure. Lockout main valve OFF,…
- Three Flashes Pressure Switch Open
- Two Flashes Control Lockout