Lennox Error Code 415

Equipment not specified:

What It Means

  • OD High Discharge Line Temp Strikes Lockout

Causes & actions from Lennox

How it shows
  • iComfort S30 alert: 415

Priority condition: Service Urgent The discharge line temperature has been consistently higher than the recommended upper limit of 279ºF. • Discharge line high temperature error count reached five strikes during a single demand. • Make sure coil is clean and airflow unobstructed in and out of condenser. • Check system charge using superheat and sub cooling temperatures. • Reset by putting outdoor control in test mode or resetting low voltage power.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.