What It Means
- High Pressure Lockout
- XP19: High Pressure Discharge Sensor Lockout

Split & Multi-Split
DS2 ON, DS1 OFF means different things on different Split & Multi-Split models. Enter your model number to see only your reading, or find your model below.
EL16XP1, ML16KP2, ML16XP1, XP15
Heat pump (outdoor)
Restricted air flow over indoor or outdoor coil. Improper refrigerant charge in system. Improper metering device installed or incorrect operation of metering device. Incorrect or improper sensor location or connection to system. Remove any blockages or restrictions from coils and/or fans. Check indoor and outdoor fan motor for proper current draws. Check system charge using subcooling method. Check system operating pressures and compare to unit subcooling tables in this instruction or located on unit access panel. Make sure all pressure switches and sensors have secure connections to system to prevent refrigerant leaks or errors in pressure and temperature measurements.
XP15
1Remove any blockages or restrictions from coils and/or fans. Check indoor and outdoor fan motor for proper current draws. 2Check system charge using approach and subcooling temperatures. 3Check system operating pressures and compare to unit charging charts. 4Make sure all pressure switches and sensors have secure connections to system to prevent refrigerant leaks or errors in pressure and temperature measurements.
High Pressure Lockout
High Pressure Lockout
High Pressure Lockout
High pressure lockout
Models: XP19
1Remove any blockages or restrictions from coils and/or fans. Check indoor and outdoor fan motor for proper current draws. 2Check system charge using approach and subcool- ing temperatures. 3Check system operating pressures and compare to unit charging charts. 4Make sure all pressure switches and sensors have secure connections to system to prevent refrigerant leaks or errors in pressure and temperature mea- surements.
High Pressure Discharge Sensor Lockout
High Pressure Discharge Sensor Lockout
Continue in ACLogics with guided diagnosis for your equipment and symptoms.