Lennox Ducted Heating

Lennox Ducted Heating Error Code E105

Ducted Heating:

What It Means

  • Device communication problem - No other devices on BUS (Communication system).

Causes & actions from Lennox

How it shows
  • Integrated control 7-segment display: E105

Equipment is unable to communicate. Indicates numerous message errors. In most cases errors are related to electrical noise. Make sure high voltage power is separated from BUS. Check for miswired and/or loose connections between the stat, indoor unit and outdoor unit. Check for a high voltage source of noise close to the system. Fault clears after communication is restored.

Other manual wording

SLP98UHV, SLP99UHV

Equipment is unable to communicate. Check for mis wire and loose connections and check for a high voltage source of noise close to the system. (welder etc.).

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.