Lennox Split & Multi-Split

Lennox Error Code E182

Split & Multi-Split

E182 means different things on different Split & Multi-Split models. Enter your model number to see only your reading, or find your model below.

What It Means

  • Suction Temperature Sensor has malfunctioned
  • Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.
  • Suction line temperature is read by the suction line temperature sensor between Pins 1 and Pin 2 of the 6-pin sensor harness. Nominal Resistance of the sensor is 10K ohms at 77F. The control will display the E182 error code if the sensor reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

Causes & actions from Lennox

Suction Temperature Sensor has malfunctioned

40 models

EL18XCV, EL18XCV-024, EL18XCV-036, EL18XCV-048, EL18XCV-060, EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060, EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060, EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060, EL22KCV, EL22KCV-024, EL22KCV-036, EL22KCV-048, EL22KCV-060, SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060, SL25KCV, SL25KCV-024, SL25KCV-036, SL25KCV-048, SL25KCV-060, SL28XCV, SL28XCV-024, SL28XCV-036, SL28XCV-048, SL28XCV-060

Air conditioner (outdoor), Heat pump (outdoor)

How it shows
  • Outdoor control 7-segment display: E182

Check temperature sensor in the applicable installation and service procedure. Nominal resistance is 10K Ohms at 77F.

Other manual wording

EL18XCV, EL18XCV-024, EL18XCV-036, EL18XCV-048, EL18XCV-060, EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060, EL19KPV,…

Sensor is open or shorted. Replace the Sensor

Applicable models & manual sources
  • EL18XCV

    Suction temperature sensor has malfunctioned.

    EL18XCV, EL18XCV-024, EL18XCV-036, EL18XCV-048, EL18XCV-060

    EL18XCV manual, page 36

  • EL18XPV

    Suction temperature sensor has malfunctioned.

    EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060

    EL18XPV manual, page 36

  • EL19KPV

    Suction temperature sensor has malfunctioned.

    EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060

    EL19KPV manual, page 42

  • EL21KLV

    Suction temperature sensor has malfunctioned.

    EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060

    EL21KLV manual, page 45

  • EL22KCV

    Suction temperature sensor has malfunctioned.

    EL22KCV, EL22KCV-024, EL22KCV-036, EL22KCV-048, EL22KCV-060

    EL22KCV manual, page 39

  • SL22KLV

    Suction temperature sensor has malfunctioned.

    SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060

    SL22KLV manual, page 42

  • SL25KCV

    Suction temperature sensor has malfunctioned.

    SL25KCV, SL25KCV-024, SL25KCV-036, SL25KCV-048, SL25KCV-060

    SL25KCV manual, page 36

  • SL28XCV

    Suction temperature sensor has malfunctioned.

    SL28XCV, SL28XCV-024, SL28XCV-036, SL28XCV-048, SL28XCV-060

    SL28XCV manual, page 30

  • EL18XCV

    Suction Temperature Sensor has malfunctioned

    EL18XCV, EL18XCV-024, EL18XCV-036, EL18XCV-048, EL18XCV-060

    EL18XCV manual, page 75

  • EL18XPV

    Suction Temperature Sensor has malfunctioned

    EL18XPV, EL18XPV-024, EL18XPV-036, EL18XPV-048, EL18XPV-060

    EL18XPV manual, page 78

  • EL19KPV

    Suction Temperature Sensor has malfunctioned

    EL19KPV, EL19KPV-024, EL19KPV-036, EL19KPV-048, EL19KPV-060

    EL19KPV manual, page 80

  • EL21KLV

    Suction Temperature Sensor has malfunctioned

    EL21KLV, EL21KLV-024, EL21KLV-036, EL21KLV-048, EL21KLV-060

    EL21KLV manual, page 91

  • EL22KCV

    Suction Temperature Sensor has malfunctioned

    EL22KCV, EL22KCV-024, EL22KCV-036, EL22KCV-048, EL22KCV-060

    EL22KCV manual, page 75

  • SL22KLV

    Suction Temperature Sensor has malfunctioned

    SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060

    SL22KLV manual, page 85

  • SL25KCV

    Suction Temperature Sensor has malfunctioned

    SL25KCV, SL25KCV-024, SL25KCV-036, SL25KCV-048, SL25KCV-060

    SL25KCV manual, page 70

  • SL28XCV

    Suction Temperature Sensor has malfunctioned

    SL28XCV, SL28XCV-024, SL28XCV-036, SL28XCV-048, SL28XCV-060

    SL28XCV manual, page 64

Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

6 models

EL18XCV, EL18XPV, EL19KPV, EL22KCV, SL25KCV, SL28XCV

Air conditioner (outdoor), Heat pump (outdoor)

How it shows
  • Outdoor control 7-segment display: E182

Suction line sensor RT41 is between pins 1 and 2 of the 4-pin harness. Nominal resistance is 10K ohms at 77F.

Applicable models & manual sources
  • EL18XCV

    Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

    EL18XCV manual, page 72

  • EL18XPV

    Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

    EL18XPV manual, page 75

  • EL19KPV

    Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

    EL19KPV manual, page 77

  • EL22KCV

    Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

    EL22KCV manual, page 72

  • SL25KCV

    Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

    SL25KCV manual, page 67

  • SL28XCV

    Suction line sensor RT41 reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

    SL28XCV manual, page 61

Suction line temperature is read by the suction line temperature sensor between Pins 1 and Pin 2 of the 6-pin sensor harness. Nominal Resistance of the sensor is 10K ohms at 77F. The control will display the E182 error code if the sensor reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

5 models

SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060

Heat pump (outdoor)

How it shows
  • Outdoor control 7-segment display: E182

This manual entry does not list further causes or actions.

Applicable models & manual sources
  • SL22KLV

    Suction line temperature is read by the suction line temperature sensor between Pins 1 and Pin 2 of the 6-pin sensor harness. Nominal Resistance of the sensor is 10K ohms at 77F. The control will display the E182 error code if the sensor reads open or shorted for 24 hours. Cooling operation is allowed with this fault.

    SL22KLV, SL22KLV-024, SL22KLV-036, SL22KLV-048, SL22KLV-060

    SL22KLV manual, page 81

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.