What It Means
- Liquid Pressure Transducer Fault

Split & Multi-Split: Air conditioner (outdoor), Heat pump (outdoor)
Liquid pressure transducer is out of range. The signal should be between 0.5 VDC and 4.5 VDC between Blue and Black. The error code will be cleared when the proper signal is provided. Systems controlled by a conventional 24VAC heat pump thermostat will operate in stage mode.
Liquid Pressure Transducer Fault