Lennox Ducted Heating

Lennox Error Code E223

Ducted Heating

E223 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.

What It Means

  • Low pressure switch failed open.
  • Pressure switch failed open.
  • SLP98UHV, SLP99UHV: Low pressure switch failed open - Refer to troubleshooting in installation instruction.

Causes & actions from Lennox

Low pressure switch failed open.

16 models

EL280UHE(X), EL280UHEK, EL280UHEK(X), EL296UHE, EL297UHEK, ML296UHVK, ML297UH045XV36BK, ML297UH070XV36BK, ML297UH090XV36CK, ML297UH090XV60CK, ML297UH110XV60CK, ML297UH135XV60DK, ML297UHVK, SL280DFNV, SL280UHV, SL297UHNV

Gas furnace (indoor)

How it shows
  • Integrated control 7-segment display: E223

Check pressure (inches w.c.) of low pressure switch clos- ing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct opera- tion and restriction. Resumes normal operation after fault is cleared

Other manual wording (1 of 2)

SL280DFNV, SL280UHV, SL297UHNV

Check pressure (inches w.c.) of low pressure switch closing on heat call. Measure operating pressure (inch- es w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Resumes normal op- eration after fault is cleared

Other manual wording (2 of 2)

EL280UHE(X), EL296UHE

Check pressure (inches w.c.) of low pressure switch closing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Resumes normal operation after fault is cleared.

Applicable models & manual sources

Pressure switch failed open.

8 models

EL180UHNE(K), EL195UHNEK, EL195UHNEK-01, EL195UHNEK-02, EL196UHEK, ML180UHVK, ML193DFEK, ML196UHEK

Gas furnace (indoor)

How it shows
  • Integrated control 7-segment display: E223

Check pressure (inches w.c.) of pressure switch closing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Resumes normal operation after fault is cleared.

Applicable models & manual sources

Low pressure switch failed open - Refer to troubleshooting in installation instruction.

Models: SLP98UHV, SLP99UHV

How it shows
  • Integrated control 7-segment display: E223

Check inches of water column pressure during operation of low pressure switch on heat call, measure inches of water column of operating pressure, inspect vent and com- bustion air inducer for correct operation and restriction.

Other manual wording

SLP99UHV

Check inches of water column pressure during operation of low pressure switch on heat call, measure inches of water column of operating pressure, inspect vent and combustion air inducer for correct operation and restriction.

Applicable models & manual sources
  • SLP98UHV

    Low pressure switch failed open − Refer to troubleshooting in installation instruc- tion.

    SLP98UHV manual, page 63

  • SLP99UHV

    Low pressure switch failed open - Refer to troubleshooting in installation instruction.

    SLP99UHV manual, page 31

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.