Lennox Ducted Heating

Lennox Error Code E225

Ducted Heating

E225 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.

What It Means

  • High pressure switch failed open.
  • SLP98UHV, SLP99UHV: High pressure switch failed open - Refer to troubleshooting in installation instruction.

Causes & actions from Lennox

High pressure switch failed open.

16 models

EL280UHE(X), EL280UHEK, EL280UHEK(X), EL296UHE, EL297UHEK, ML296UHVK, ML297UH045XV36BK, ML297UH070XV36BK, ML297UH090XV36CK, ML297UH090XV60CK, ML297UH110XV60CK, ML297UH135XV60DK, ML297UHVK, SL280DFNV, SL280UHV, SL297UHNV

Gas furnace (indoor)

How it shows
  • Integrated control 7-segment display: E225

Check pressure (inches w.c.) of high pressure switch clos- ing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct opera- tion and restriction. Resumes normal operation after fault is cleared.

Other manual wording (1 of 2)

SL280DFNV, SL280UHV, SL297UHNV

Check pressure (inches w.c.) of high pressure switch closing on heat call. Measure operating pressure (inch- es w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Resumes normal op- eration after fault is cleared.

Other manual wording (2 of 2)

EL280UHE(X), EL296UHE

Check pressure (inches w.c.) of high pressure switch closing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Resumes normal operation after fault is cleared.

Applicable models & manual sources

High pressure switch failed open - Refer to troubleshooting in installation instruction.

Models: SLP98UHV, SLP99UHV

How it shows
  • Integrated control 7-segment display: E225

Check inches of water column pressure of high pressure switch on heat call, measure inches of water column of operating pressure, inspect vent and combustion air induc- er for correct operation and restriction.

Other manual wording

SLP99UHV

Check inches of water column pressure of high pressure switch on heat call, measure inches of water column of operating pressure, inspect vent and combustion air inducer for correct operation and restriction.

Applicable models & manual sources
  • SLP98UHV

    High pressure switch failed open − Refer to troubleshooting in installation instruc- tion.

    SLP98UHV manual, page 63

  • SLP99UHV

    High pressure switch failed open - Refer to troubleshooting in installation instruction.

    SLP99UHV manual, page 31

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.