What It Means
- Ignition on high fire
- EL280UHE(X), EL296UHE: Ignition on High Fire - Information Only.

Ducted Heating
E229 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.
EL280UHEK, EL280UHEK(X), EL297UHEK, ML296UHVK, ML297UH045XV36BK, ML297UH070XV36BK, ML297UH090XV36CK, ML297UH090XV60CK, ML297UH110XV60CK, ML297UH135XV60DK, ML297UHVK, SL280DFNV, SL280UHV, SL297UHNV
Gas furnace (indoor)
IFC switched to high fire ignition because low fire pressure switch did not close in allowed time. No action is needed.
SL280DFNV, SL280UHV, SL297UHNV
IFC switched to high fire ignition because low fire pres- sure switch did not close in allowed time. No action is needed.
Ignition on high fire
EL280UHEK, EL280UHEK(X)
Ignition on high fire
Ignition on high fire
Ignition on high fire
ML297UH045XV36BK, ML297UH070XV36BK, ML297UH090XV36CK, ML297UH090XV60CK, ML297UH110XV60CK, ML297UH135XV60DK, ML297UHVK
Ignition on high fire
Ignition on high fire
Ignition on high fire
Models: EL280UHE(X), EL296UHE
Code is displayed if 1) low pressure switch fails to close, then furnace will switch to high speed inducer to close both low and high pressure switches, then furnace lights on high fire, or 2) if continuous fan is active, furnace lights on high fire for 60 seconds to improve heat exchanger warm up time.
Ignition on High Fire - Information Only.
Ignition on High Fire - Information Only.
Continue in ACLogics with guided diagnosis for your equipment and symptoms.