Lennox Ducted Heating

Lennox Error Code E294

Ducted Heating

E294 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.

What It Means

  • SLP98UHV, SLP99UHV: Combustion air inducer motor amp draw is too high.
  • SL280DFNV, SL297UHNV: Combustion air inducer over current.

Causes & actions from Lennox

Combustion air inducer motor amp draw is too high.

Models: SLP98UHV, SLP99UHV

How it shows
  • Integrated control 7-segment display: E294

Check combustion blower bearings, wiring , am- peres, replace if it does not operate or meet perfor- mance.

Other manual wording

SLP99UHV

Check combustion blower bearings, wiring , amperes, replace if it does not operate or meet performance.

Applicable models & manual sources

Combustion air inducer over current.

Models: SL280DFNV, SL297UHNV

How it shows
  • Integrated control 7-segment display: E294

Check combustion blower bearings, wiring and amps. Re- place if does not operate or does not meet performance standards. Clears after inducer current is sensed to be in- range after the ignition following the soft lockout or reset.

Applicable models & manual sources
Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →