Lennox Ducted Heating

Lennox Error Code E311

Ducted Heating

E311 means different things on different Ducted Heating models. Enter your model number to see only your reading, or find your model below.

What It Means

  • Heat rate reduced to match indoor blower air flow.
  • SLP98UHV, SLP99UHV: Heat rate reduced to match indoor blower air flow. Replace filter or repair duct restriction.

Causes & actions from Lennox

Heat rate reduced to match indoor blower air flow.

11 models

ML296UHVK, ML297UH045XV36BK, ML297UH070XV36BK, ML297UH090XV36CK, ML297UH090XV60CK, ML297UH110XV60CK, ML297UH135XV60DK, ML297UHVK, SL280DFNV, SL280UHV, SL297UHNV

Gas furnace (indoor)

How it shows
  • Integrated control 7-segment display: E311

Warning Only. Furnace blower in cutback mode due to restricted airflow. Reduce firing rate every 60 seconds to match available CFM. Check filter and duct system. To clear, replace filter if needed or repair/ add duct. 2-stage controls will reduce firing rate to 1st stage. Clears when heat call finishes successfully.

Other manual wording

ML296UHVK, ML297UH045XV36BK, ML297UH070XV36BK, ML297UH090XV36CK, ML297UH090XV60CK, ML297UH110XV60CK, ML297UH135XV60DK, ML297UHVK

Warning Only. Furnace blower in cutback mode due to restricted airflow. Reduce firing rate every 60 seconds to match available CFM. Check filter and duct sytem. To clear, replace filter if needed or repair/add duct. 2 stage controls will reduce firing rate to 1st stage. Clears when heat call finishes successfully

Applicable models & manual sources

Heat rate reduced to match indoor blower air flow. Replace filter or repair duct restriction.

Models: SLP98UHV, SLP99UHV

How it shows
  • Integrated control 7-segment display: E311

Furnace blower in cutback mode due to restricted airflow. Check filter and ductwork. To clear replace filter if needed or repair/ add ductwork.

Applicable models & manual sources
  • SLP98UHV

    Heat rate reduced to match indoor blower air flow. Replace filter or repair duct restriction.

    SLP98UHV manual, page 64

  • SLP99UHV

    Heat rate reduced to match indoor blower air flow. Replace filter or repair duct restriction.

    SLP99UHV manual, page 32

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.