What It Means
- G24M: After combustion blower starts: pressure CLOSED? NO: check main valve OFF; hold until switch CLOSES; fast flash. Ignition trial7seconds after45second prepurge: flame not registered, valve and spark OFF, increment trial register; three completed trials give ignition reset, combustion/system fans OFF, wait60minutes; fast flash. During running flame loss, start spark within0.8seconds maximum, test recovery within7seconds; failure turns valve/spark OFF and retries. After run limit/pressure switch closes combustion fan ON, system fan OFF after selected delay; fast flash. Parenthetical holding/reset is extraction annotation, not a lamp code.
- G24M: Thermostat calls for heat; normal heating sequence begins. Fast flash alone also occurs on the separate pressure-hold and ignition-reset branches; operating stage matters.