What It Means
- G24M: 5.1 - Unit operates with a cooling and continuous fan demand. - Combustion air blower energizes with Heating demand. - Ignitor is energized but unit fails to light. LED#1-Alternating Slow Flash LED#2-Alternating Slow Flash
- G24M: 6.2 - Combustion air blower energizes with a heating demand. - BBurners lliighhtt bbutt ffaiill tto sttay lit. - After 5 tries the control diagnostics flash the watchguard burners failed to ignite code. LED#1-Alternating Slow Flash LED#2-Alternating Slow Flash
- G24M: 6.4 - Combustion air blower energizes with a heating demand. - Burners light roughly and the unit fails to stay lit. - Diagnostic lights flash watchguard flame failure. LED#1-Alternating Slow Flash LED#2-Alternating Slow Flash
- G24M: 6.5 - Combustion air blower energizes with a heating demand. - Burners light. - Diagnostic lights flash watch guard flame failure. - NOTE" Unit might go into 60 minute Watchguard mode depending on intermittent nature of sensor signal. LED#1-Alternating Slow Flash LED#2-Alternating Slow Flash