Lennox Ducted Heating

Lennox Error Code LED#1-Fast Flash, LED#2-Slow Flash

Ducted Heating:

What It Means

  • 1.3 - On initial power-up the comb. air blower does not energize. - Diagnostic lights flash the reverse polarity code. LED#1-Fast Flash, LED#2-Slow Flash.

Causes & actions from Lennox

How it shows
  • SureLight board LEDs (DS1/DS2): LED#1-Fast Flash, LED#2-Slow Flash (led1: flashing (fast), led2: flashing (slow))

Possible cause: 1.3.1 120V main power polarity reversed. Corresponding action/comments: ACTION 1 − Check the 120V has line and neutral correctly input into control. ACTION 2 − Reverse the line and neutral at the 112200VV field connection..

Applicable models & manual sources
  • G24M

    1.3 − On initial power−up the comb. air blower does not energize.. − Diagnostic lights flash the reverse polarity code. LED#1−Fast Flash, LED#2−Slow Flash.

    G24M manual, page 31

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.