Lennox Error Code LED#1-Off, LED#2-Off

Ducted Heating:

What It Means

  • 1.1 - Both diagnostic lights fail to light up. LED#1-Off LED#2-Off

Causes & actions from Lennox

How it shows
  • SureLight board LEDs (DS1/DS2): LED#1-Off, LED#2-Off (led1: off, led2: off)

Possible cause: 1.1.1 Main voltage 120V not supplied to unit. Corresponding action/comments: ACTION 1 − Check 120V main voltage. Determine cause of main power failure. Possible cause: 1.1.2 Miswiring of furnace or improper connections. Corresponding action/comments: ACTION 1 − Check for correct wiring of 120V to power make up box and transformer. ACTION 2 − Check 24V wiring to control board. Possible cause: 1.1.3 Circuit breaker tripped or fails to close. Corresponding action/comments: ACTION 1 − Replace circuit breaker if it is reset but does not have continuity. ACTION 2 − If circuit breaker still trips, check for short. Possible cause: 1.1.4 Door interlock switch failure. Corresponding action/comments: ACTION 1 − Check that door switch is activated when door is closed. ACTION 2 − Check wire connections to switch, re- place loose connectors. ACTION 3 − Check continuity of switch in closed position. Replace if malfunctioning Possible cause: 1.1.5 Transformer Failure. Corresponding action/comments: ACTION 1 − Check that transformer output is 24V. Replace if malfunctioning Possible cause: 1.1.6 Failed control board. Corresponding action/comments: ACTION 1 − If all the above items have been checked, replace board.

Applicable models & manual sources
  • G24M

    1.1 − Both diagnostic lights fail to light up. LED#1−Off LED#2−Off

    G24M manual, page 31

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →