Lennox Ducted Heating

Lennox Error Code LED #1: OFF, LED #2: SLOW FLASH

Ducted Heating:

What It Means

  • Pressure switch open or has opened 5 times during a single call for heat; OR: Blocked inlet/exhaust vent; OR: Condensate line blocked; OR: Pressure switch closed prior to activation of combustion air blower.

Causes & actions from Lennox

How it shows
  • SureLight board LEDs (DS1/DS2): LED #1: OFF, LED #2: SLOW FLASH (led1: off, led2: flashing (slow))

This manual entry does not list further causes or actions.

Applicable models & manual sources
  • G24M

    Pressure switch open or has opened 5 times during a single call for heat; OR: Blocked inlet/exhaust vent; OR: Condensate line blocked; OR: Pressure switch closed prior to activation of combustion air blower.

    G24M manual, page 9

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →