Lennox Ducted Heating

Lennox Error Code LED #1 ON / LED #2 SLOW FLASH

Ducted Heating:

What It Means

  • Rollout CLOSED? NO: gas valve OFF, combustion air blower OFF, indoor blower OFF with delay; hold until rollout closes. LED1 ON AND LED2 SLOW flash.

Causes & actions from Lennox

How it shows
  • SureLight board LEDs (DS1/DS2): LED #1 ON / LED #2 SLOW FLASH (led1: on, led2: flashing (slow))

Rollout switch open. Gas valve off, combustion air blower off, indoor blower off with delay. Sequence holds until rollout switch closes.

Applicable models & manual sources
  • G24M

    Rollout CLOSED? NO: gas valve OFF, combustion air blower OFF, indoor blower OFF with delay; hold until rollout closes. LED1 ON AND LED2 SLOW flash.

    G24M manual, page 27

Disclaimer: This information is for general reference. Code wording and instructions vary by model. Always follow the service manual for your exact unit.

What should you check next?

Continue in ACLogics with guided diagnosis for your equipment and symptoms.

See how guided diagnosis works →