What It Means
- 3.1 - Unit operates with a cooling or continuous fan demand. - Combustion air blower will not start with a Heating demand. - Diaggnostic ligghts flash the limit failure modde. LED#1-Slow Flash, LED#2-On

Ducted Heating:
Possible cause: 3.1.1 Primary or secondary (if equipped) limit open. Corresponding action/comments: ACTION 1 − Check continuity across switch(es). Switches reset automatically upon cool down. ACTION 2 − Check for restrictions on blower inlet air (including filter) and outlet air. Determine cause for limit activation before placing unit back in operation. Possible cause: 3.1.2 Miswiring of furnace or improper con- nections at limit switch(es). Corresponding action/comments: ACTION 1 − Check for correct wiring and loose connections. Correct wiring and/or replace any loose connections.
3.1 − Unit operates with a cooling or con- tinuous fan demand. − Combustion air blower will not start with a Heating demand. − Diaggnostic ligghts flash the limit failure modde. LED#1−Slow Flash, LED#2−On